3-6
Chapter 3 INSTALLATION
4
1
2
3
5
6
7
8
9
10
Chapter 3 INSTALLATION
3-7
4. Connecting to the power
Attach the power connector to the power cable and insert it into the "AC IN" connector on
the front panel of the controller as shown below.
4.1 Power supply connection example
L
N
L1
N1
Leakage
breaker
Noise
filter
Circuit
protector
Circuit
protector
Surge
absorber
Electro-
magnetic
contactor
RCX240
Single phase
AC 200V
See 4.6.
See 4.5.
See 4.8.
See 4.7.
See 4.9.
Connection example
c
CAUTION
Do not make incorrect terminal connections. Incorrect connections may cause
malfunction.