4-218
Chapter 4 OPERATION
4
1
2
3
5
6
7
8
9
10
Chapter 4 OPERATION
4-219
12. "SYSTEM" mode
6. Incremental Mode control /INCMOD
This parameter sets whether to have origin incomplete status every time power to this controller
is turned on. This is automatically set invalid when the parameters are initialized.
n
NOTE
• When this parameter is valid (enabled), return-to-origin will always be incomplete
each time the controller power is turned on. Absolute reset must therefore
always be performed.
• Enable this parameter if the controller does not have an absolute battery
installed.
c
CAUTION
This parameter must be disabled (invalid) if the robot has an axis using the mark
method for origin detection.
1
Select "6. Incremental Mode control" in "SYSTEM>PARAM>OTHERS"
mode.
2
Press
(EDIT).
SYSTEM
>PARAM>OTHERS V10.01
2.Data display length 6char
3.Parameter display unit PULSE
4.DO cond. on EMG HOLD
5.Watch on STD.DIO DC24V VALID
6.Incremental Mode control INVALID
INVALID VALID
Setting "Incremental Mode control"
3
Press
(INVALID) or
(VALID) to enter the setting.
4
Press
to quit the edit mode.
Summary of Contents for RCX240
Page 1: ...RCX240 EUR6127206 E107 Ver 2 06 Userʼs Manual YAMAHA 4 AXIS ROBOT CONTROLLER ...
Page 2: ......
Page 18: ......
Page 34: ......
Page 78: ......
Page 402: ......
Page 448: ...5 46 Chapter 5 TWO ROBOT SETTING MEMO ...
Page 450: ......
Page 480: ...6 30 Chapter 6 PARALLEL I O INTERFACE MEMO ...
Page 482: ......
Page 494: ......
Page 506: ......
Page 512: ......
Page 522: ......
Page 611: ...INDEX ...
Page 612: ......
Page 617: ......
Page 619: ......