A
A-10
TROUBLESHOOTING
[ 2] Robot operating area errors
TROUBLESHOOTING
A-11
2.17 : Arch condition bad
Code
: &H0211
Meaning/Cause
Action
On SCARA robots and XY robots, arch
motion is not used on X and Y axes when
arch position data is in mm units.
On SCARA robots, arch motion is not
used on X and Y axes when target
position data is in mm units.
Change to correct arch motion
command.
2.18 : RIGHTY now selected
Code
: &H0212
Meaning/Cause
Action
On SCARA type robots, the arm will now
use the right-handed system for starting
Cartesian movement.
−−−
2.19 : LEFTY now selected
Code
: &H0213
Meaning/Cause
Action
On SCARA type robots, arm will now use
the left-handed system for starting
Cartesian movement.
−−−
2.20 : Illegal hand type
Code
: &H0214
Meaning/Cause
Action
An R-axis hand definition was attempted
on a robot not having an R-axis.
1. Change to Y-axis hand definition.
2. Do not use a hand definition.
2.22 : Arm length is 0
Code
: &H0216
Meaning/Cause
Action
When arm length setting is 0 on SCARA
type robots, movement on Cartesian
coordinates was attempted.
1. Set standard coordinates.
2. Set the arm length parameter.
2.23 : Cannot move (RIGHTY to LEFTY)
Code
: &H0217
Meaning/Cause
Action
Interpolation movement shifting from the
right-handed system to the left-handed
system was executed with a SCARA
robot.
Check the current hand system and
point data hand system flag.
Summary of Contents for RCX240
Page 1: ...RCX240 EUR6127206 E107 Ver 2 06 Userʼs Manual YAMAHA 4 AXIS ROBOT CONTROLLER ...
Page 2: ......
Page 18: ......
Page 34: ......
Page 78: ......
Page 402: ......
Page 448: ...5 46 Chapter 5 TWO ROBOT SETTING MEMO ...
Page 450: ......
Page 480: ...6 30 Chapter 6 PARALLEL I O INTERFACE MEMO ...
Page 482: ......
Page 494: ......
Page 506: ......
Page 512: ......
Page 522: ......
Page 611: ...INDEX ...
Page 612: ......
Page 617: ......
Page 619: ......