Chapter 4 OPERATION
12. "SYSTEM" mode
Chapter 4 OPERATION
4-219
5. Watch on STD.DIO DC24V /STDWCH
This parameter sets whether or not to enable the dedicated interlock signal input when there
is no STD.DIO DC24V power being supplied. This is automatically enabled (valid) when the
parameters are initialized.
n
NOTE
When DC 24V is supplied to the STD. DIO and SAFETY connector, this parameter is
enabled (valid) regardless of the setting.
1
Select "5. Watch on STD.DIO DC24V" in "SYSTEM>PARAM>OTHERS"
mode.
2
Press
(EDIT).
SYSTEM
>PARAM>OTHERS V10.01
1.Display language(JPN/ENG) ENGLISH
2.Data display length 6char
3.Parameter display unit PULSE
4.DO cond. on EMG HOLD
5.Watch on STD.DIO DC24V VALID
INVALID VALID
Setting the "Watch on STD.DIO DC24V"
c
CAUTION
• Make sure this setting is enabled (valid) when the robot will be in normal
operation.
• the interlock signal sends a stop command such as for stopping robot operation.
If the interlock setting is off (disabled) use caution during robot operation.
3
Press
(INVALID) or
(VALID) to enter the setting.
4
Press
to quit the edit mode.
Summary of Contents for RCX240
Page 1: ...RCX240 EUR6127206 E107 Ver 2 06 Userʼs Manual YAMAHA 4 AXIS ROBOT CONTROLLER ...
Page 2: ......
Page 18: ......
Page 34: ......
Page 78: ......
Page 402: ......
Page 448: ...5 46 Chapter 5 TWO ROBOT SETTING MEMO ...
Page 450: ......
Page 480: ...6 30 Chapter 6 PARALLEL I O INTERFACE MEMO ...
Page 482: ......
Page 494: ......
Page 506: ......
Page 512: ......
Page 522: ......
Page 611: ...INDEX ...
Page 612: ......
Page 617: ......
Page 619: ......