3-12
Chapter 3 INSTALLATION
4
1
2
3
5
6
7
8
9
10
Chapter 3 INSTALLATION
3-13
4.7 Installing an electromagnetic contactor
When controlling the power on/off operation of the robot controller using an external unit such
as a PLC, an electromagnetic contactor should be installed on the AC power supply line for the
controller. Select an electromagnetic contactor that falls under the required safety category and
control the open/close operation using a circuit that meets the safety category. In this case, separate
the main power supply line from the control power supply line, and install the electromagnetic
contactor on the main power supply side.
To control the operation using emergency stop, turn the main power on and off.
4.8 Installing a noise filter
To comply with CE marking requirements, use a noise filter to suppress the noise on the power
supply line.
Manufacturer : SOSHIN ELECTRIC CO., LTD.
Type No.
: NF2020A-UP
85
±
1
(71.6)
70
±
0.5
φ
4.5
(18)
34
±
0.5
40
±
0.5
50
±
1
40
±
1
(28.8)
10
No.
Part name
q
w
e
r
t
Input terminal
Case
Name plate
Output terminal
Earth terminal
Note
M4
PBT
M4
M4
q
t
w
e
r
R2.25, Length: 6
6-M4
t
Dimensional outlines of recommended noise filter
4. Connecting to the power
Summary of Contents for RCX240
Page 1: ...RCX240 EUR6127206 E107 Ver 2 06 Userʼs Manual YAMAHA 4 AXIS ROBOT CONTROLLER ...
Page 2: ......
Page 18: ......
Page 34: ......
Page 78: ......
Page 402: ......
Page 448: ...5 46 Chapter 5 TWO ROBOT SETTING MEMO ...
Page 450: ......
Page 480: ...6 30 Chapter 6 PARALLEL I O INTERFACE MEMO ...
Page 482: ......
Page 494: ......
Page 506: ......
Page 512: ......
Page 522: ......
Page 611: ...INDEX ...
Page 612: ......
Page 617: ......
Page 619: ......