4
1
2
3
5
6
7
8
9
10
4-260
Chapter 4 OPERATION
12. "SYSTEM" mode
Chapter 4 OPERATION
4-261
6
Press
to quit the editing.
To continue setting other items, use the cursor (
/
) keys to select them.
Example: When the comparison points are set as shown below, and the robot axis tip is moved
between the marks, the output is off at
and the output is on at
. (when
"5. Condition" is set to "IN")
n
NOTE
By changing the "5. Condition" setting, it is possible to select whether the robot
position should be within a specified area or outside it in order to turn on the output
status.
When points are designated in Cartesian coordinates ("mm" unit system)
Comparison point 2
+Z
+X
+Y
Comparison point 1