4
1
2
3
5
6
7
8
9
10
4-266
Chapter 4 OPERATION
12. "SYSTEM" mode
Chapter 4 OPERATION
4-267
3. Operating device in "SERVICE" mode
Specify the operating device to use.
Description
RPB
Only RPB operation is allowed.
RPB/DI
Allows RPB and dedicated input.
RPB/COM
Allows RPB and online commands.
ALL
Allows operation by all devices.
n
NOTE
The settings made here are only valid until the controller power is turned off. Save
these settings if you want to use them again after power is turned off.
w
WARNING
SETTINGS MAY BE CHANGED BUT THE CUSTOMER MUST BEAR RESPONSIBILITY FOR
THEM. THE CUSTOMER SHOULD kEEP SAFETY IN MIND WHEN MAkING CHANGES.
1
Select "3. Operating device" in "SYSTEM>OPTION>SERVICE" mode.
2
Press
(EDIT).
SYSTEM
>OPTION>SERVICE V10.01
1.Service level LEVEL3
2.Movement Vel <3%
3.Operating device
RPB
RPB RPB/DI
RPB/COM
ALL
Editing the "SERVICE" mode devices
3
Press a key from
(RPB) to
(ALL) to select the operating device.
4
Press
to quit the editing.
To continue setting other items, use the cursor (
/
) keys to select them.
Summary of Contents for RCX240
Page 1: ...RCX240 EUR6127206 E107 Ver 2 06 Userʼs Manual YAMAHA 4 AXIS ROBOT CONTROLLER ...
Page 2: ......
Page 18: ......
Page 34: ......
Page 78: ......
Page 402: ......
Page 448: ...5 46 Chapter 5 TWO ROBOT SETTING MEMO ...
Page 450: ......
Page 480: ...6 30 Chapter 6 PARALLEL I O INTERFACE MEMO ...
Page 482: ......
Page 494: ......
Page 506: ......
Page 512: ......
Page 522: ......
Page 611: ...INDEX ...
Page 612: ......
Page 617: ......
Page 619: ......