3-16
Chapter 3 INSTALLATION
4
1
2
3
5
6
7
8
9
10
Chapter 3 INSTALLATION
3-17
7. I/O connections
The various input/output (I/O) signals from peripheral equipment can be connected to the robot
controller. Each I/O is set with a number, and the I/O connector to be used depends on that
number.
For more detailed information on inputs and outputs, see Chapter 6, "PARALLEL I/O INTERFACE" or
see Chapter 7, "SAFETY I/O INTERFACE".
The following describes terms used in the manual.
l
NPN specifications
NPN specifications indicate that a DO (digital output) type NPN open-collector transistor is
used for the I/O port having a transistor and photocoupler, and a corresponding DI (digital
input) is also used. NPN specifications therefore make use of a sink output and a source input (see
drawing below).
Current
Current
DO output (sink type)
DI input (source type)
N.COM
P.COM
NPN
Connection for NPN specifications
l
PNP specifications
PNP specifications indicate that a DO (digital output) type PNP open-collector transistor is used
for the I/O port having a transistor and photocoupler, and a corresponding DI (digital input)
is also used. PNP specifications therefore make use of a source output and a sink input (see
drawing below).
DO output (source type)
DI input (sink type)
Current
Current
N.COM
P.COM
PNP
Connection for PNP specifications
7. I/O connections
Summary of Contents for RCX240
Page 1: ...RCX240 EUR6127206 E107 Ver 2 06 Userʼs Manual YAMAHA 4 AXIS ROBOT CONTROLLER ...
Page 2: ......
Page 18: ......
Page 34: ......
Page 78: ......
Page 402: ......
Page 448: ...5 46 Chapter 5 TWO ROBOT SETTING MEMO ...
Page 450: ......
Page 480: ...6 30 Chapter 6 PARALLEL I O INTERFACE MEMO ...
Page 482: ......
Page 494: ......
Page 506: ......
Page 512: ......
Page 522: ......
Page 611: ...INDEX ...
Page 612: ......
Page 617: ......
Page 619: ......