Commands listed in alphabetical order
Arguments
CH<x>
designates an analog channel as the bus SPI clock source.
CH<x>_D<x>
designates an digital channel as the bus SPI clock source.
MATH<x>
designates a math waveform as the clock source.
REF<x>
designates a reference waveform as the clock source.
REF<x>_D<x>
speci
fi
es a digital reference waveform as the clock source
waveform for the speci
fi
ed SPI bus.
Examples
BUS:B1:SPI:CLOCK:SOURCE CH5
sets the SPI clock source for the bus B1
to CH5.
BUS:B1:SPI:CLOCK:SOURCE?
might return
:BUS:B1:SPI:CLOCK:SOURCE
MATH1
, indicating that the SPI clock source for the bus B1 is set to MATH1.
BUS:B<x>:SPI:CLOCk:THReshold
This command sets or queries the SPI Clock (SCLK) source threshold for the
speci
fi
ed bus. The bus is speci
fi
ed by x.
Conditions
Requires option SR-EMBD.
Group
Bus
Syntax
BUS:B<x>:SPI:CLOCk:THReshold <NR3>
BUS:B<x>:SPI:CLOCk:THReshold?
Arguments
<NR3>
is the SPI Clock (SCLK) source threshold for the speci
fi
ed bus.
Examples
BUS:B1:SPI:CLOCk:THReshold 50.0e-3
sets the threshold to 50.0 mV.
BUS:B1:SPI:CLOCk:THReshold?
might return
:BUS:B1:SPI:CLOCK:THRESHOLD 0.0E+0
indicating the threshold is set to
0.0 V.
BUS:B<x>:SPI:DATa:POLarity
This command sets or queries the SPI data (SDA) source polarity for the bus
number speci
fi
ed by x.
Conditions
Requires option SR-EMBD.
MSO54, MSO56, MSO58, MSO58LP Programmer
2-171
Summary of Contents for MSO54
Page 1: ...xx 5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual P077130502 077 1305 02 ...
Page 2: ......
Page 3: ...5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual xx www tek com 077 1305 02 ...
Page 8: ...Preface iv MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 26: ...Command Syntax 2 10 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 936: ...Status and Events 3 20 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 937: ...Appendix A Character Set MSO54 MSO56 MSO58 MSO58LP Programmer A 1 ...
Page 938: ...Appendix A Character Set A 2 MSO54 MSO56 MSO58 MSO58LP Programmer ...