Commands listed in alphabetical order
Arguments
INTERnal
speci
fi
es the internal 10 MHz crystal oscillator as the time base
reference.
EXTernal
speci
fi
es the user-supplied external signal as the time base reference.
Examples
ROSC:SOURCE INTERNAL
speci
fi
es the internal 10 MHz crystal oscillator as
the time base reference.
ROSC:SOURCE?
might return
:ROSC:SOURCE INTERNAL
, indicating that the
10 MHz crystal oscillator is being used as the time base reference.
ROSc:STATE? (Query Only)
This query-only command returns whether the time base reference oscillator is
locked. This command will return either LOCKED or UNLOCKED.
Group
Miscellaneous
Syntax
ROSc:STATE?
Returns
LOCKED
indicates the reference oscillator is locked.
UNLOCKED
indicates the reference oscillator is not locked.
Examples
ROSC:STATE?
might return
:ROSC:STATE LOCKED
, indicating that the time
base reference is locked.
*RST (No Query Form)
This command (no query form) resets the instrument to the factory default settings.
This command does the following:
Recalls the default instrument setup.
Clears the current *DDT command.
Disables aliases (:ALIAS:STATE 0).
Disables the user password (for the *PUD command).
MSO54, MSO56, MSO58, MSO58LP Programmer
2-615
Summary of Contents for MSO54
Page 1: ...xx 5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual P077130502 077 1305 02 ...
Page 2: ......
Page 3: ...5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual xx www tek com 077 1305 02 ...
Page 8: ...Preface iv MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 26: ...Command Syntax 2 10 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 936: ...Status and Events 3 20 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 937: ...Appendix A Character Set MSO54 MSO56 MSO58 MSO58LP Programmer A 1 ...
Page 938: ...Appendix A Character Set A 2 MSO54 MSO56 MSO58 MSO58LP Programmer ...