![background image](http://html1.mh-extra.com/html/omron/sysmac-cs1d-cpu/sysmac-cs1d-cpu_reference-manual_7422681301.webp)
1262
Model Conversion Instructions (Unit Ver. 3.0 or Later)
Section 3-35
Examples
Specifying a Later Task
When CIO 000000 is ON in the following example, task number 3 is put into
standby status in task number 1. Task number 3 will be not be executed in the
that cycle when program execution reaches task number 3.
Specifying an Earlier Task
When CIO 000000 is ON in the following example, task number 1 is put into
standby status in task number 3. Task number 1 will be not be executed in the
next cycle when program execution reaches task number 1.
3-35 Model Conversion Instructions (Unit Ver. 3.0 or Later)
This section describes instructions used when changing PLC models.
03
Task number 3 is in standby
status in the same cycle,
i.e., it is not executed in the
current or following cycles.
Task 1
Task 3
01
Task number 1 is in standby
status in the next cycle, i.e.,
it is executed in the current
cycle but not in following
cycles.
Task 1
Task 3
Instruction
Mnemonic
Function code
Page
BLOCK TRANSFER
XFERC
565
1264
SINGLE WORD DISTRIBUTE
DISTC
566
1267
Summary of Contents for SYSMAC CS1D-CPU**
Page 3: ...iv...
Page 29: ...xxx...
Page 185: ...146 List of Instructions by Function Code Section 2 4...
Page 1389: ...1350 CJ series Instruction Execution Times and Number of Steps Section 4 2...
Page 1390: ...1351 Appendix A ASCII Code Table ASCII SP Four leftmost bits Four rightmost bits...