![background image](http://html1.mh-extra.com/html/omron/sysmac-cs1d-cpu/sysmac-cs1d-cpu_reference-manual_7422681314.webp)
1275
Model Conversion Instructions (Unit Ver. 3.0 or Later)
Section 3-35
Description
MOVBC(568) copies the specified bit (n) from S to the specified bit (m) in D.
The other bits in the destination word are left unchanged.
Note
The same word can be specified for both S and D to copy a bit within a word.
Flags
Note
In C-series PLCs, the MOVE BIT (MOVB) instruction will cause the Error Flag
to go ON if the content of an indirectly addressed DM word (*DM) is not BCD,
or the DM area boundary is exceeded. MOVBC(568) will not cause the Error
Flag to go ON in these cases.
EM Area with bank
En_00000 to En_32767
(n = 0 to C)
Indirect DM/EM
addresses in binary
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
Indirect DM/EM
addresses in BCD
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
Constants
#0000 to #FFFF
(binary)
Specified values
only
---
Data Registers
DR0 to DR15
Index Registers
---
Indirect addressing
using Index Registers
,IR0 to ,IR15
–2048 to +2047, IR0 to –2048 to +2047, IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –) IR0 to, –(– –) IR15
Area
S
C
D
Name
Label
Operation
Error Flag
ER
ON if the rightmost and leftmost two digits of C are not
BCD or outside of the specified range of 00 to 15.
OFF in all other cases.
Summary of Contents for SYSMAC CS1D-CPU**
Page 3: ...iv...
Page 29: ...xxx...
Page 185: ...146 List of Instructions by Function Code Section 2 4...
Page 1389: ...1350 CJ series Instruction Execution Times and Number of Steps Section 4 2...
Page 1390: ...1351 Appendix A ASCII Code Table ASCII SP Four leftmost bits Four rightmost bits...
Page 1391: ...1352 ASCII Code Table Appendix A...