CHAPTER 16 I
2
C BUS
User’s Manual U16896EJ2V0UD
494
(2) Start ~ Code ~ Data ~ Start ~ Address ~ Data ~ Stop
<1> When WTIM0 bit = 0 (after restart, address match)
ST
AD6 to AD0
R/W
ACK
D7 to D0
ACK
ST
AD6 to AD0
R/W
ACK
D7 to D0
ACK
SP
S
1
S
2
S
3
S
4
Δ
5
S
1: IICS0 register = 0010X010B
S
2: IICS0 register = 0010X000B
S
3: IICS0 register = 0001X110B
S
4: IICS0 register = 0001X000B
Δ
5: IICS0 register = 00000001B
Remark
S
: Always generated
Δ
: Generated only when SPIE0 bit = 1
X:
don’t
care
<2> When WTIM0 bit = 1 (after restart, address match)
ST
AD6 to AD0
R/W
ACK
D7 to D0
ACK
ST
AD6 to AD0
R/W
ACK
D7 to D0
ACK
SP
S
1
S
2
S
3
S
4
S
5
Δ
6
S
1: IICS0 register = 0010X010B
S
2: IICS0 register = 0010X110B
S
3: IICS0 register = 0010XX00B
S
4: IICS0 register = 0001X110B
S
5: IICS0 register = 0001XX00B
Δ
6: IICS0 register = 00000001B
Remark
S
: Always generated
Δ
: Generated only when SPIE0 bit = 1
X:
don’t
care