15.4.2 Single transfer mode
(1) Usage
In the receive-only mode (CSIM0n.TRMDn bit = 0), communication is started by reading the SIRBn/SIRBnL
register.
In the transmission/reception mode (TRMDn bit = 1), communication is started by writing to the
SOTBn/SOTBnL register.
In the slave mode, the operation must be enabled beforehand (CSIM0n.CSI0En bit = 1).
When communication is started, the value of the CSIM0n.CSOTn bit becomes 1 (transmission execution
status).
Upon communication completion, the transmission/reception completion interrupt request signal (INTCSI0n)
is generated, and the CSOTn bit is cleared (0). The next data communication request is then waited for.
Caution When the CSOTn bit = 1, do not manipulate the CSI0n register.
Remark
n = 0, 1