GE Power Systems
Gas Turbine
Scheduled Turbine Maintenance
Reformated, September 1991
RUNNING INSPECTIONS
Running inspections consist of observations made while a unit is in service. The turbine should be observed
on a programmed schedule which should be established as part of the unit maintenance program consistent
with the operator’s requirements.
Housekeeping
In addition to the detailed maintenance procedures which follow, the daily (or short-term) observation of
Gas Turbine operation and appearance must be considered. The following checklist will provide assis-
tance when establishing routine maintenance programs for gas turbines.
Control Cab
**WARNING**
Observe all safety notices and precautions when occu-
pying the unit control cab.
1. Check the condition of turbine generator control panel and motor control center lamps.
Note:
Replacement of bulbs while unit is operating could result in inadver-
tent unit shutdown.
2. Observe that all instruments are functional and readable; clean glass faces when dirty, and replace
broken glasses.
3. Periodically check the filter element in the compartment air conditioner; clean it as necessary.
4. Inspect for evidence of loose or chafing wires, and schedule corrective action, if required.
5. Clean the floor.
6. Note battery charger output level.
Schedule Turbine Maintenance
Rev. 0 (11/98)
STM-1
Summary of Contents for MS6001B
Page 2: ...Gas Turbine Inspection and Maintenance GEK 107048 I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 4: ...Inspection and Maintenance Note THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 13: ...INSERT TAB INTRODUCTION ...
Page 14: ......
Page 25: ...INSERT TAB STANDARD PRACTICES ...
Page 26: ......
Page 87: ...INSERT TAB AUXILIARY CONTROLS SYSTEMS MAINTENANCE ...
Page 88: ......
Page 133: ...INSERT TAB SCHEDULED TURBINE MAINTENACE ...
Page 134: ......
Page 157: ...INSERT TAB COMBUSTION INSPECTION ...
Page 158: ......
Page 239: ...INSERT TAB HOT GAS PATH INSPECTION ...
Page 240: ......
Page 313: ...INSERT TAB MAJOR INSPECTION ...
Page 314: ......
Page 316: ...Inspection and Maintenance GEK 107048 Major Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 363: ...INSERT TAB MAINTENANCE FORMS ...
Page 364: ......