Inspection and Maintenance
Auxiliary and Controls Systems Maintenance
ACSM–13
Inspection
Document
or Page
Reference
Inspection
Frequency and
Turbine Status
What to Inspect for
INLET SYSTEMS (TURBINE)
Inlet Screen
Obstructions
M — O
IMP–32
Bypass Door
Proper Seal
Limit Switch Operation
M — O
A — S
IMP–34
Inlet Compartment Inlet
Ductwork and Silencers
Sealing
Cleanliness
Entrapped Material
A — S
A — S
A — S
IMP–34
Inlet Guide Vanes
Corrosion Pitting
A — S
IMP–34
Moisture Separators
(if applicable)
Cleanliness of Media Section
Build Up on Blades
M — O
A — S
IMP–34
Inlet Filtration System
Refer to the Maintenance Section of
the Manufacturer’s Operation and
Maintenance Manual contained in
Volume II.
Evaporative Cooler
(if applicable)
Lubricate Motor
Tanks for Debris
Media Buildup
Nozzles Plugging
Spray Pattern
Clean Tank
A — O
A — S
A — S
M — O
A — S
A — S
IMP–35
Water Flow Adjustment
Proper Water Flow Media Wetness
D — O
IMP–35
Pump Operation
Secure Prior to Unit Shutdown
D — O
IMP–35
Summary of Contents for MS6001B
Page 2: ...Gas Turbine Inspection and Maintenance GEK 107048 I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 4: ...Inspection and Maintenance Note THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 13: ...INSERT TAB INTRODUCTION ...
Page 14: ......
Page 25: ...INSERT TAB STANDARD PRACTICES ...
Page 26: ......
Page 87: ...INSERT TAB AUXILIARY CONTROLS SYSTEMS MAINTENANCE ...
Page 88: ......
Page 133: ...INSERT TAB SCHEDULED TURBINE MAINTENACE ...
Page 134: ......
Page 157: ...INSERT TAB COMBUSTION INSPECTION ...
Page 158: ......
Page 239: ...INSERT TAB HOT GAS PATH INSPECTION ...
Page 240: ......
Page 313: ...INSERT TAB MAJOR INSPECTION ...
Page 314: ......
Page 316: ...Inspection and Maintenance GEK 107048 Major Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 363: ...INSERT TAB MAINTENANCE FORMS ...
Page 364: ......