Inspection and Maintenance
Auxiliary and Controls Systems Maintenance
ACSM–7
Inspection
Document
or Page
Reference
Inspection
Frequency and
Turbine Status
What to Inspect for
Cooling Water Radiator Fan
Module
Dirty Wheel Housing, Ducts and
Screens
Excessive Vibration Noise
Damaged Blades
Loose Mounting Bolts
Air Flow Obstructed
Rust, Corrosion and Peeling
A — S
A — O
A — S
A — S
A — S
A — S
IMP–11
Cooling Water Pump
Leakage Shaft Seal
Dirty Shaft Seal Cooling Water Line
and Filter Element
Excessive Wear Ring Clearance
Excessive Mechanical Seal Wear
M — O
A — S
Maj — S
Maj — S
IMP–11
FALSE START DRAIN VALVE
False Start Drain Valve
Incorrect Sequencing During Startup
and Shutdown
Improper Operation of Valve Actuator
Air and Oil Leaks
Worn Diaphragm in Valve Actuator
A — O
A — O
D — O
A — S
IMP–12
SPEEDTRONIC
Control Loop
Flow Unstable, Hot Starts,
Overtemperature
Calibration FSR Versus Fuel Flow
LVDTs
Electronic Trip Actuation of 20FL and
20HD
Check 20FL for Proper Null Bias
LVDT Feedback at Firing Speed
Versus FSR
D — O
A — S
SA — S
SA — S
A — O
Control
Specification–
Operating
Instructions and
Sequences and
Control
Specification–
Control System
Adjustments
Summary of Contents for MS6001B
Page 2: ...Gas Turbine Inspection and Maintenance GEK 107048 I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 4: ...Inspection and Maintenance Note THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 13: ...INSERT TAB INTRODUCTION ...
Page 14: ......
Page 25: ...INSERT TAB STANDARD PRACTICES ...
Page 26: ......
Page 87: ...INSERT TAB AUXILIARY CONTROLS SYSTEMS MAINTENANCE ...
Page 88: ......
Page 133: ...INSERT TAB SCHEDULED TURBINE MAINTENACE ...
Page 134: ......
Page 157: ...INSERT TAB COMBUSTION INSPECTION ...
Page 158: ......
Page 239: ...INSERT TAB HOT GAS PATH INSPECTION ...
Page 240: ......
Page 313: ...INSERT TAB MAJOR INSPECTION ...
Page 314: ......
Page 316: ...Inspection and Maintenance GEK 107048 Major Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 363: ...INSERT TAB MAINTENANCE FORMS ...
Page 364: ......