Inspection and Maintenance — GEK 107048
Hot Gas Path Inspection — Inspection Procedures
HGP-I-14
Figure HGP-I.13. Radial Seal Pin Groove Repair Limits.
Farside
Only
0.700 Inch
0.500 Inch
Total Amt of
Missing Metal
Allowed Each
Side
0.35 Inch
Blending
Allowed
In This Region
Region
IV
Region
III
Region
II
Region
I
Nearside
and
Farside
No Missing
Material
Allowed
No Missing
Metal Allowed