Selecting the number of drive data sets
Parameter p0180 defines the number of drive data sets (1 ... 4).
Parameter
Description
p0010 = 0
Drive commissioning: Ready
p0010 = 15
Drive commissioning: Data sets
p0180
Drive data set (DDS) number
Copying the drive data sets
Parameter
Description
p0819[0]
Source drive data set
p0819[1]
Target drive data set
p0819[2] = 1
Starts the copy operation
Parameters
Number
Name
Factory setting
p0010
Drive commissioning parameter filter
1
r0051
CO/BO: Drive data set DDS effective
-
p0180
Drive data set (DDS) number
1
p0819[0 … 2]
Copy drive data set DDS
0
p0820[C]
BI: Drive data set DDS selection, bit 0
0
p0821[C]
BI: Drive data set DDS selection, bit 1
0
p0826[M]
Motor changeover, motor number
0
More information
The converter switches the motor data set (MDS) and the power unit data set (PDS) together
with the drive data set (DDS).