p1005[0...n]
CO: Fixed speed setpoint 5 / n_set_fixed 5
Access level: 2
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: p2000
Dynamic index: DDS, p0180
Unit group: 3_1
Unit selection: p0505
Function diagram: 3010
Min:
-210000.000 [rpm]
Max:
210000.000 [rpm]
Factory setting:
0.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 5.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024, r1197
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1006[0...n]
CO: Fixed speed setpoint 6 / n_set_fixed 6
Access level: 2
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: p2000
Dynamic index: DDS, p0180
Unit group: 3_1
Unit selection: p0505
Function diagram: 3010
Min:
-210000.000 [rpm]
Max:
210000.000 [rpm]
Factory setting:
0.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 6.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024, r1197
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1007[0...n]
CO: Fixed speed setpoint 7 / n_set_fixed 7
Access level: 2
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: p2000
Dynamic index: DDS, p0180
Unit group: 3_1
Unit selection: p0505
Function diagram: 3010
Min:
-210000.000 [rpm]
Max:
210000.000 [rpm]
Factory setting:
0.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 7.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024, r1197
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1008[0...n]
CO: Fixed speed setpoint 8 / n_set_fixed 8
Access level: 2
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: p2000
Dynamic index: DDS, p0180
Unit group: 3_1
Unit selection: p0505
Function diagram: 3010
Min:
-210000.000 [rpm]
Max:
210000.000 [rpm]
Factory setting:
0.000 [rpm]
Description:
Setting and connector output for fixed speed setpoint 8.
Dependency:
See also: p1020, p1021, p1022, p1023, r1024, r1197
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Parameters
7.2 Parameter list
SINAMICS G120X converter
610
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......