Note
Value = 2 is only possible for Control Units with RS485 as a field bus interface.
p2040
Fieldbus interface monitoring time / Fieldbus t_monit
G120X_USS
Access level: 3
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 9310
Min:
0 [ms]
Max:
1999999 [ms]
Factory setting:
1000 [ms]
Description:
Sets the monitoring time to monitor the process data received via the fieldbus interface.
If no process data is received within this time, then an appropriate message is output.
Dependency:
See also: F01910
Note
p2040 = 0:
Monitoring is deactivated.
For p2030 = 2 (Modbus RTU) or p2030 = 5 (BACnet MS/TP) the following deviation applies:
Factory setting: 10000
p2042
PROFIBUS Ident Number / PB ident No.
G120X_DP
Access level: 3
Calculated: -
Data type: Integer16
Can be changed: T
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: -
Min:
0
Max:
1
Factory setting:
0
Description:
Sets the PROFIBUS ident number (PNO-ID).
SINAMICS can be operated with various identities on PROFIBUS. This allows the use of a PROFIBUS GSD that is
independent of the device (e.g. PROFIdrive VIK-NAMUR with ident number 3AA0 hex).
Value:
0:
SINAMICS
1:
VIK-NAMUR
Note
Every change only becomes effective after a POWER ON.
r2043.0...2
BO: PROFIdrive PZD state / PD PZD state
G120X_DP,
G120X_PN
Access level: 3
Calculated: -
Data type: Unsigned8
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 2410
Min:
-
Max:
-
Factory setting:
-
Description:
Displays the PROFIdrive PZD state.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Setpoint failure
Yes
No
-
02
Fieldbus operation
Yes
No
-
Dependency:
See also: p2044
Note
When using the "setpoint failure" signal, the bus can be monitored and an application-specific response triggered when
the setpoint fails.
Parameters
7.2 Parameter list
SINAMICS G120X converter
744
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......