r1084
CO: Speed limit positive effective / n_limit pos eff
Access level: 3
Calculated: -
Data type: FloatingPoint32
Can be changed: -
Scaling: p2000
Dynamic index: -
Unit group: 3_1
Unit selection: p0505
Function diagram: 3050, 7958
Min:
- [rpm]
Max:
- [rpm]
Factory setting:
- [rpm]
Description:
Display and connector output for the active positive speed limit.
Dependency:
See also: p1082, p1083, p1085
Note
Vector control: r1084 <= 60 x 240 Hz / r0313
p1085[0...n]
CI: Speed limit in positive direction of rotation / n_limit pos
Access level: 3
Calculated: -
Data type: Unsigned32 /
FloatingPoint32
Can be changed: T
Scaling: p2000
Dynamic index: CDS, p0170
Unit group: -
Unit selection: -
Function diagram: 3050
Min:
-
Max:
-
Factory setting:
1083[0]
Description:
Sets the signal source for the speed limit of the positive direction.
p1086[0...n]
CO: Speed limit in negative direction of rotation / n_limit neg
Access level: 3
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: p2000
Dynamic index: DDS, p0180
Unit group: 3_1
Unit selection: p0505
Function diagram: 3050
Min:
-210000.000 [rpm]
Max:
0.000 [rpm]
Factory setting:
-210000.000 [rpm]
Description:
Sets the speed limit for the negative direction.
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
r1087
CO: Speed limit negative effective / n_limit neg eff
Access level: 3
Calculated: -
Data type: FloatingPoint32
Can be changed: -
Scaling: p2000
Dynamic index: -
Unit group: 3_1
Unit selection: p0505
Function diagram: 3050, 7958
Min:
- [rpm]
Max:
- [rpm]
Factory setting:
- [rpm]
Description:
Display and connector output for the active negative speed limit.
Dependency:
See also: p1082, p1086, p1088
Note
Vector control: r1087 >= -60 x 240 Hz / r0313
p1088[0...n]
CI: Speed limit in negative direction of rotation / n_limit neg
Access level: 3
Calculated: -
Data type: Unsigned32 /
FloatingPoint32
Can be changed: T
Scaling: p2000
Dynamic index: CDS, p0170
Unit group: -
Unit selection: -
Function diagram: 3050
Min:
-
Max:
-
Factory setting:
1086[0]
Parameters
7.2 Parameter list
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
627
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......