p1829
Compensation valve lockout time phase V / Comp t_lock ph V
G120X_DP (PM330),
G120X_PN (PM330),
G120X_USS (PM330)
Access level: 4
Calculated: CALC_MOD_ALL Data type: FloatingPoint32
Can be changed: T, U
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: -
Min:
0.00 [µs]
Max:
7.80 [µs]
Factory setting:
0.00 [µs]
Description:
Sets the valve lockout time to compensate for phase V.
p1830
Compensation valve lockout time phase W / Comp t_lock ph W
Access level: 4
Calculated: CALC_MOD_ALL Data type: FloatingPoint32
Can be changed: T, U
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: -
Min:
0.00 [µs]
Max:
3.99 [µs]
Factory setting:
0.00 [µs]
Description:
Sets the valve lockout time to compensate for phase W.
p1830
Compensation valve lockout time phase W / Comp t_lock ph W
G120X_DP (PM330),
G120X_PN (PM330),
G120X_USS (PM330)
Access level: 4
Calculated: CALC_MOD_ALL Data type: FloatingPoint32
Can be changed: T, U
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: -
Min:
0.00 [µs]
Max:
7.80 [µs]
Factory setting:
0.00 [µs]
Description:
Sets the valve lockout time to compensate for phase W.
p1832
Dead time compensation current level / t_dead_comp I_lev
Access level: 4
Calculated: CALC_MOD_ALL Data type: FloatingPoint32
Can be changed: T, U
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: -
Min:
0.0 [Arms]
Max:
10000.0 [Arms]
Factory setting:
0.0 [Arms]
Description:
Sets the current level for the dead time compensation.
Above the current level, the dead time - resulting from the converter switching delays - is compensated by a previously
calculated constant value. If the relevant phase current setpoint falls below the absolute value defined by p1832, the
corrective value for this phase is continuously reduced.
Dependency:
The factory setting of p1832 is automatically set to 0.02 * rated drive converter current (r0207).
r1838.0...15
CO/BO: Gating unit status word 1 / Gating unit ZSW1
Access level: 3
Calculated: -
Data type: Unsigned16
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description:
Display and BICO output for status word 1 of the power unit.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Fault time-critical
ON
OFF
-
01
Gating unit mode bit 0
ON
OFF
-
02
Pulse enable
ON
OFF
-
03
Switch-off signal path STO_B
Inactive
Active
-
04
Switch-off signal path STO_A
Inactive
Active
-
Parameters
7.2 Parameter list
SINAMICS G120X converter
716
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......