p2044
PROFIdrive fault delay / PD fault delay
G120X_DP,
G120X_PN
Access level: 3
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 2410
Min:
0 [s]
Max:
100 [s]
Factory setting:
0 [s]
Description:
Sets the delay time to initiate fault F01910 after a setpoint failure.
The time until the fault is initiated can be used by the application. This means that is is possible to respond to the failure
while the drive is still operational (e.g. emergency retraction).
Dependency:
See also: r2043
See also: F01910
p2047
PROFIBUS additional monitoring time / PB suppl t_monit
G120X_DP
Access level: 3
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 2410
Min:
0 [ms]
Max:
20000 [ms]
Factory setting:
0 [ms]
Description:
Sets the additional monitoring time to monitor the process data received via PROFIBUS.
Enables short bus faults to be compensated.
If no process data is received within this time, then an appropriate message is output.
Dependency:
See also: F01910
Note
For controller STOP, the additional monitoring time is not effective.
r2050[0...11]
CO: PROFIdrive PZD receive word / PZD recv word
Access level: 3
Calculated: -
Data type: Integer16
Can be changed: -
Scaling: 4000H
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 2440, 2468,
9360
Min:
-
Max:
-
Factory setting:
-
Description:
Connector output to interconnect PZD (setpoints) with word format received from the fieldbus controller.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
NOTICE
Where there is a multiple interconnection of a connector output, all the connector inputs must either have Integer or
FloatingPoint data types. A BICO interconnection for a single PZD can only take place either on r2050 or r2060.
Parameters
7.2 Parameter list
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
745
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......