Description:
Displays the actual rotor resistance (phase value).
The parameter is affected by the motor temperature model.
Dependency:
See also: p0354, p0620
Note
In each case, only the rotor resistance of the active Motor Data Set is included with the rotor temperature of the thermal
motor model.
This parameter is not used for synchronous motors (p0300 = 2xx).
p0500
Technology application / Tec application
Access level: 2
Calculated: -
Data type: Integer16
Can be changed: C2(1), T
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: -
Min:
0
Max:
5
Factory setting:
0
Description:
Sets the technology application.
The parameter influences the calculation of open-loop and closed-loop control parameters that is e.g. initiated using
p0340 = 5.
Value:
0:
Standard drive
1:
Pumps and fans
2:
Sensorless closed-loop control down to f = 0 (passive loads)
3:
Pumps and fans, efficiency optimization
5:
Starting with a high break loose torque
Dependency:
For p0096 = 1, 2 (Standard, Dynamic Drive Control) p0500 cannot be changed.
NOTICE
If the technological application is set to p0500 = 0 ... 3 during commissioning (p0010 = 1, 5, 30), the operating mode
(p1300) is pre-set accordingly.
Parameters
7.2 Parameter list
SINAMICS G120X converter
536
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......