6.5.1.1
Analog input as setpoint source
Function description
$QDORJLQSXWDFWXDOYDOXH
0DLQVHWSRLQW
6FDOLQJ
6FDOLQJ
6XSSOHPHQWDU\VHWSRLQW
S
S
S
U
U
S
$,
$,
U>@
Figure 6-39
Example: Analog input 0 as setpoint source
In the quick commissioning, you define the preassignment for the converter interfaces.
Depending on what has been preassigned, after quick commissioning, the analog input can be
interconnected with the main setpoint.
Example
Setting with analog input 0 as setpoint source:
Parameter
Description
p1070 = 755[0]
Interconnects main setpoint with analog input 0
p1075 = 755[0]
Interconnects supplementary setpoint with analog input 0
Parameters
Number
Name
Factory setting
r0755[0 … 1]
CO: CU analog inputs, actual value in percent
- %
p1070[C]
CI: Main setpoint
Dependent on the
converter
p1071[C]
CI: Main setpoint scaling
1
r1073
CO: Main setpoint active
- rpm
p1075[C]
CI: Supplementary setpoint
0
p1076[C]
CI: Supplementary setpoint scaling
1
r1077
CO: Supplementary setpoint effective
- rpm
Advanced commissioning
6.5 Setpoints and setpoint processing
SINAMICS G120X converter
328
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......