Note
For bit 02:
A data set changeover is delayed by the time required for the internal parameter calculation.
For bit 04:
A data set changeover is only carried out when the armature short circuit is not activated.
For bit 05:
A data set changeover is only carried out when pole position identification is not running.
For bit 07:
A data set changeover is only carried out when rotating measurement is not running.
For bit 08:
A data set changeover is only carried out when motor data identification is not running.
r0836.0...1
CO/BO: Command Data Set CDS selected / CDS selected
Access level: 3
Calculated: -
Data type: Unsigned8
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 8560
Min:
-
Max:
-
Factory setting:
-
Description:
Displays the command data set (CDS) selected via the binector input.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
CDS selection bit 0
ON
OFF
-
01
CDS selection bit 1
ON
OFF
-
Dependency:
See also: r0050, p0810, p0811
Note
Command data sets are selected via binector input p0810 and following.
The currently effective command data set is displayed in r0050.
r0837.0...1
CO/BO: Drive Data Set DDS selected / DDS selected
Access level: 3
Calculated: -
Data type: Unsigned8
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 8565
Min:
-
Max:
-
Factory setting:
-
Description:
Displays the drive data set (DDS) selected via the binector input.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DDS selection bit 0
ON
OFF
-
01
DDS selection bit 1
ON
OFF
-
Dependency:
See also: r0051, p0820, p0821
Note
Drive data sets are selected via binector input p0820 and following.
The currently effective drive data set is displayed in r0051.
If there is only one data set, then a value of 0 is displayed in this parameter and not the selection via binector inputs.
Parameters
7.2 Parameter list
SINAMICS G120X converter
586
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......