Description:
Sets the bearing version.
Corresponding to the bearing version entered, its code number (p0531) is automatically set.
0 = No data
1 = Manual entry
101 = STANDARD
102 = PERFORMANCE
103 = HIGH PERFORMANCE
104 = ADVANCED LIFETIME
Dependency:
See also: p0301, p0531, p0532, p1082
NOTICE
For p0530 = 101, 102, 103, 104, the maximum bearing speed (p0532) is write protected. Write protection is withdrawn
with p0530 = 1.
If p0530 is changed during quick commissioning (p0010 = 1), then the maximum speed p1082, which is also
associated with quick commissioning, is pre-assigned appropriately. This is not the case when commissioning the
motor (p0010 = 3). The maximum speed of the bearing is factored into the limit for the maximum speed p1082.
Note
For a motor with DRIVE-CLiQ, p0530 can only be set to 1.
p0531[0...n]
Bearing code number selection / Bearing codeNo sel
Access level: 3
Calculated: -
Data type: Unsigned16
Can be changed: C2(3)
Scaling: -
Dynamic index: MDS, p0130
Unit group: -
Unit selection: -
Function diagram: -
Min:
0
Max:
65535
Factory setting:
0
Description:
Display and setting the code number of the bearing.
When setting p0301 and p0530 the code number is automatically pre-assigned and is write protected. The information
in p0530 should be observed when removing write protection.
Dependency:
See also: p0301, p0530, p0532, p1082
NOTICE
If p0531 is changed during quick commissioning (p0010 = 1), then the maximum speed p1082, which is also
associated with quick commissioning, is pre-assigned appropriately. This is not the case when commissioning the
motor (p0010 = 3). The maximum speed of the bearing is factored into the limit for the maximum speed p1082.
Note
p0531 cannot be changed on a motor with DRIVE-CLiQ.
p0532[0...n]
Bearing maximum speed / Bearing n_max
Access level: 3
Calculated: -
Data type: FloatingPoint32
Can be changed: C2(1, 3)
Scaling: -
Dynamic index: MDS, p0130
Unit group: -
Unit selection: -
Function diagram: -
Min:
0.0 [rpm]
Max:
210000.0 [rpm]
Factory setting:
0.0 [rpm]
Description:
Sets the maximum speed of the bearing.
The following applies when calculating the maximum speed (p1082):
- for p0324 = 0 or p0532 = 0, p0322 is used.
- for p0324 > 0 and p0532 > 0, the minimum value from the two parameters is used.
Dependency:
See also: p0301, p0322, p0530, p1082
Parameters
7.2 Parameter list
SINAMICS G120X converter
544
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......