690 V converters
Frame Size
Rated power based on
LO (kW)
Output current (A) (at 45 °C ambient temperature) for a
pulse frequency of
2 kHz
4 kHz
FSD
3
6
3.6
4
7
4.2
5.5
10
6
7.5
13
7.8
11
16
9.6
15
21
12.6
18.5
25
15
22
29
17.4
30
38
22.8
37
46
27.6
FSE
45
58
34.8
55
68
40.8
FSF
75
90
54
90
112
67.2
110
128
76.8
132
158
94.8
FSG
160
196
118
200
236
142
250
288
173
FSH
315
330
215
1)
355
385
250
1)
400
420
273
1)
450
470
306
1)
FSJ
500
520
338
1)
560
580
377
1)
630
650
423
1)
The rated output currents in bold refer to the default pulse frequency at 45 °C ambient temperature.
1)
In the factory setting, the converter starts with a pulse frequency of 4 kHz and reduces automatically
the pulse frequency to the associated required frequencies when loaded. When the load decreases,
the pulse frequency is increased automatically up to 4 kHz.
The values of the rated current refer to a pulse frequency of 2 kHz at 45 °C ambient temperature and
are reached at any time by the automatic adaptation of the output pulse frequency.
Technical data
11.5 Derating data
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
1097
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......