04
Start ramp-function generator
Yes
No
-
05
Wait for execution
Yes
No
-
06
Slope filter act
Yes
No
-
07
Positive gradient
Yes
No
-
08
Current < threshold
Yes
No
-
09
Current minimum
Yes
No
-
10
Search in the positive direction
Yes
No
-
11
Stop after positive direction
Yes
No
-
12
Stop after negative direction
Yes
No
-
13
No result
Yes
No
-
14
Fast flying restart w/ voltage model for induction motor activ. Yes
No
-
15
Flying restart with VSM active
Yes
No
-
r1205.0...21
CO/BO: Flying restart vector control status / FlyRest vector st
Access level: 4
Calculated: -
Data type: Unsigned32
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description:
Display and connector output for the status for checking and monitoring flying restart states in the vector control mode.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Speed adaptation circuit record angle
Yes
No
-
01
Speed adaptation circuit set gain to 0
Yes
No
-
02
Isd channel enable
Yes
No
-
03
Speed control switched out
Yes
No
-
04
Quadrature arm switched in
Yes
No
-
05
Special transformation active
Yes
No
-
06
Speed adaptation circuit set I component to 0
Yes
No
-
07
Current control on
Yes
No
-
08
Isd_set = 0 A
Yes
No
-
09
Frequency held
Yes
No
-
10
Search in the positive direction
Yes
No
-
11
Search Started
Yes
No
-
12
Current impressed
Yes
No
-
13
Search interrupted
Yes
No
-
14
Speed adaptation circuit deviation = 0
Yes
No
-
15
Speed control activated
Yes
No
-
16
Fast flying restart w/ voltage model for induction motor activ. Yes
No
-
17
Fast flying restart w/ voltage model for induction motor exited Yes
No
-
18
Apply VSM voltage to the monitor
Yes
No
-
19
Preassign flux ramp
Yes
No
-
20
Adaptation current controller and speed adapt. controller gain Yes
No
-
21
Voltage pulse active
Yes
No
-
Note
For bit 00 ... 09:
Used to control internal sequences during the flying restart.
Depending on the motor type (p0300), the number of active bits differs.
For bits 10 ... 15:
Are used to monitor the flying restart sequence.
Parameters
7.2 Parameter list
SINAMICS G120X converter
646
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......