6.3.8
Jogging
Overview
The "Jog" function is typically used to temporarily move a motor using local control commands.
Requirement
The OFF1 command must be active. With an active ON command, the converter ignores the
commands "Jogging 1" and "Jogging 2".
Function description
5HDG\WRVZLWFKRQ
2SHUDWLRQ
QRMRJJLQJ
-RJJLQJ
Commands "Jog 1" or "Jog 2" switch the motor on and off.
The commands are only active when the converter is in the "Ready for switching on" state.
0RWRUVSHHG
0D[LPXPVSHHG
-RJJLQJ
6HWSRLQWMRJJLQJ
6HWSRLQWMRJJLQJ
-RJJLQJ
S
S
S
W
W
W
S
S
Figure 6-27
Behavior of the motor when "jogging"
After switching on, the motor accelerates to the setpoint, jog 1 or setpoint, jog 2. The two
different setpoints can, for example, be assigned to motor clockwise and counter-clockwise
rotation.
When jogging, the same ramp-function generator is active as for the ON/OFF1 command.
Example
Parameter
Description
p1055 = 722.0
Jogging bit 0: Select jogging 1 via digital input 0
p1056 = 722.1
Jogging bit 1: Select jogging 2 via digital input 1
Advanced commissioning
6.3 Drive control
SINAMICS G120X converter
290
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......