r0374[0...n]
Motor rotor resistance cold / Mot R_r cold
Access level: 4
Calculated: -
Data type: FloatingPoint32
Can be changed: -
Scaling: -
Dynamic index: MDS, p0130
Unit group: -
Unit selection: -
Function diagram: -
Min:
- [ohm]
Max:
- [ohm]
Factory setting:
- [ohm]
Description:
Displays the motor rotor resistance at an ambient temperature p0625.
Dependency:
See also: p0625
Note
The parameter is not used for synchronous motors (p0300 = 2xx).
r0376[0...n]
Rated motor rotor resistance / Mot rated R_rotor
Access level: 4
Calculated: -
Data type: FloatingPoint32
Can be changed: -
Scaling: -
Dynamic index: MDS, p0130
Unit group: -
Unit selection: -
Function diagram: -
Min:
- [ohm]
Max:
- [ohm]
Factory setting:
- [ohm]
Description:
Displays the nominal rotor resistance of the motor at the rated temperature.
The rated temperature is the sum of p0625 and p0628.
Dependency:
See also: p0628
Note
The parameter is not used for synchronous motors (p0300 = 2xx).
r0377[0...n]
Motor leakage inductance total / Mot L_leak total
Access level: 4
Calculated: -
Data type: FloatingPoint32
Can be changed: -
Scaling: -
Dynamic index: MDS, p0130
Unit group: -
Unit selection: -
Function diagram: 6640, 6714,
6721, 6828, 6834, 6836
Min:
- [mH]
Max:
- [mH]
Factory setting:
- [mH]
Description:
Displays the stator leakage inductance of the motor including the motor reactor (p0233).
r0382[0...n]
Motor magnetizing inductance transformed / Mot L_magn transf
Access level: 4
Calculated: -
Data type: FloatingPoint32
Can be changed: -
Scaling: -
Dynamic index: MDS, p0130
Unit group: -
Unit selection: -
Function diagram: -
Min:
- [mH]
Max:
- [mH]
Factory setting:
- [mH]
Description:
Displays the magnetizing inductance of the motor.
Note
The parameter is not used for synchronous motors (p0300 = 2xx).
r0384[0...n]
Motor rotor time constant / damping time constant d axis / Mot T_rotor/T_Dd
Access level: 3
Calculated: -
Data type: FloatingPoint32
Can be changed: -
Scaling: -
Dynamic index: MDS, p0130
Unit group: -
Unit selection: -
Function diagram: 6722, 6837
Min:
- [ms]
Max:
- [ms]
Factory setting:
- [ms]
Parameters
7.2 Parameter list
SINAMICS G120X converter
534
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......