Number
Name
p1520[0...n]
CO: Torque limit upper / M_max upper
p2000
Reference speed reference frequency / n_ref f_ref
p2001
Reference voltage / Reference voltage
p2002
Reference current / I_ref
p2003
Reference torque / M_ref
p2006
Reference temperature / Ref temp
p2030
Fieldbus interface protocol selection / Fieldbus protocol
p2038
PROFIdrive STW/ZSW interface mode / PD STW/ZSW IF mode
p2079
PROFIdrive PZD telegram selection extended / PZD telegr ext
p7763
KHP OEM exception list number of indices for p7764 / KHP OEM qty p7765
p7764[0...n]
KHP OEM exception list / KHP OEM excep list
p11026
Free tec_ctrl 0 unit selection / Ftec0 unit sel
p11126
Free tec_ctrl 1 unit selection / Ftec1 unit sel
p11226
Free tec_ctrl 2 unit selection / Ftec2 unit sel
8.6.1
Extending the exception list for know-how protection
In the factory setting, the exception list only includes the password for know-how protection.
Before activating know-how protection, you can additionally enter the adjustable parameters in
the exception list, which must still be able to be read and changed by end users – even if know-
how protection has been activated.
You do not need to change the exception list, if, with exception of the password, you do not
require additional adjustable parameters in the exception list.
Absolute know-how protection
If you remove password p7766 from the exception list, it is no longer possible to enter or change
the password for know-how protection.
You must reset the converter to the factory settings in order to be able to gain access to the
converter adjustable parameters. When restoring the factory settings, you lose what you have
configured in the converter, and you must recommission the converter.
Parameter
Parameter
Description
Factory setting
p7763
KHP OEM exception list, number of indices for p7764
1
p7764[0…p7763]
KHP OEM exception list
p7766 is the password for know-how protection
[0] 7766
[1...499] 0
Saving the settings and series commissioning
8.6 Know-how protection
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
955
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......