S7-400H
System Manual, 03/2012, A5E00267695-11
77
Special functions of a CPU 41x-H
6
6.1
Security levels
You can define a security level for your project in order to prevent unauthorized access to
the CPU programs. The objective of these security level settings is to grant a user access to
specific programming device functions which are not protected by password, and to allow
that user to execute those functions on the CPU. When logged on with a password, the user
may execute all PG functions.
Setting security levels
You can set the CPU security levels 1 to 3 under "STEP 7/Configure Hardware".
If you do not know the password, you can clear the set security level by means of a manual
memory reset using the mode selector. No Flash card must be inserted in the CPU when
you perform such an operation.
The following table lists the security levels of an S7–400 CPU.
Table 6- 1
Security levels of a CPU
CPU function
Security level 1
Security level 2
Security level 3
Display of list of blocks
Access granted
Access granted
Access granted
Monitor variables
Access granted
Access granted
Access granted
Module status STACKS
Access granted
Access granted
Access granted
Operator control and monitoring
functions
Access granted
Access granted
Access granted
S7 communication
Access granted
Access granted
Access granted
Reading the time
Access granted
Access granted
Access granted
Setting the time
Access granted
Access granted
Access granted
Block status
Access granted
Access granted
Password required
Load in PG
Access granted
Access granted
Password required
Load in CPU
Access granted
Password required
Password required
Delete blocks
Access granted
Password required
Password required
Compress memory
Access granted
Password required
Password required
Download user program to
memory card
Access granted
Password required
Password required
Controlling selection
Access granted
Password required
Password required
Modify variable
Access granted
Password required
Password required
Breakpoint
Access granted
Password required
Password required
Clear breakpoint
Access granted
Password required
Password required
Memory reset
Access granted
Password required
Password required
Содержание SIMATIC S7-400H
Страница 24: ...Preface 1 1 Preface S7 400H 24 System Manual 03 2012 A5E00267695 11 ...
Страница 46: ...Getting Started 4 5 Special layout features of SIMATIC Manager S7 400H 46 System Manual 03 2012 A5E00267695 11 ...
Страница 120: ...Memory concept 10 1 Overview of the memory concept of S7 400H CPUs S7 400H 120 System Manual 03 2012 A5E00267695 11 ...
Страница 258: ...Communication 14 8 General issues regarding communication S7 400H 258 System Manual 03 2012 A5E00267695 11 ...
Страница 354: ...Synchronization modules 18 3 Selecting fiber optic cables S7 400H 354 System Manual 03 2012 A5E00267695 11 ...
Страница 434: ...Technical data 20 6 Runtimes of the FCs and FBs for redundant I Os S7 400H 434 System Manual 03 2012 A5E00267695 11 ...
Страница 460: ...Function modules and communication processors supported by the S7 400H S7 400H 460 System Manual 03 2012 A5E00267695 11 ...