Determining memory requirements using SIMATIC Manager
You can view the block lengths offline in the "Properties - Block folder offline" dialog box
(Blocks > Object Properties > Blocks tab).
The offline view shows the following lengths:
●
Size (sum of all blocks, without system data) in the load memory of the target system
●
Size (sum of all blocks, without system data) in the work memory of the target system
Block lengths on the programming device (PG/PC) are not shown in the properties of the
block container.
Block lengths are shown in "byte" units.
The following values are shown in the properties of a block:
●
Required local data volume: Length of local data in bytes
●
MC7: Length of MC7 code in bytes
●
Length of DB user data
●
Length in load memory of the target system
●
Length in work memory of the target system (only if hardware assignment is known)
The views always show these block data, regardless whether it is located in the window of
an online view or of an offline view.
When a block container is opened and "View Details" is set, the project window always
indicates work memory requirements, regardless of whether the block container appears in
the window of an online or offline view.
You can add up the block lengths by selecting all relevant blocks. SIMATIC Manager outputs
the total length of the selected blocks in its status bar.
Lengths of blocks (VATs, for example) which can not be downloaded to the target system
are not shown.
Block lengths on the programming device (PG/PC) are not shown in the Details view.
See also
Содержание SIMATIC S7-400H
Страница 24: ...Preface 1 1 Preface S7 400H 24 System Manual 03 2012 A5E00267695 11 ...
Страница 46: ...Getting Started 4 5 Special layout features of SIMATIC Manager S7 400H 46 System Manual 03 2012 A5E00267695 11 ...
Страница 120: ...Memory concept 10 1 Overview of the memory concept of S7 400H CPUs S7 400H 120 System Manual 03 2012 A5E00267695 11 ...
Страница 258: ...Communication 14 8 General issues regarding communication S7 400H 258 System Manual 03 2012 A5E00267695 11 ...
Страница 354: ...Synchronization modules 18 3 Selecting fiber optic cables S7 400H 354 System Manual 03 2012 A5E00267695 11 ...
Страница 434: ...Technical data 20 6 Runtimes of the FCs and FBs for redundant I Os S7 400H 434 System Manual 03 2012 A5E00267695 11 ...
Страница 460: ...Function modules and communication processors supported by the S7 400H S7 400H 460 System Manual 03 2012 A5E00267695 11 ...