Assembly of a CPU 41x–H
5.1 Operator controls and display elements of the CPUs
S7-400H
50
System Manual, 03/2012, A5E00267695-11
PROFINET interface
You can connect PROFINET IO devices to the PROFINET interface. The PROFINET
interface features two switched ports with external connectors (RJ 45). The PROFINET
interface provides the interconnection with Industrial Ethernet.
CAUTION
This interface only allows connection to an Ethernet LAN. You cannot connect it to the
public telecommunication network, for example.
You may only connect PROFINET-compliant network components to this interface.
Setting the rack number
Use the switch on the rear panel of the CPU to set the rack number. The switch has two
positions: 1 (up) and 0 (down). One CPU is allocated rack number 0, and the partner CPU is
assigned rack number 1. The default setting of all CPUs is rack number 0.
Connecting an external backup voltage to the "EXT. BATT." socket
The S7–400H power supply modules support the use of two backup batteries. This allows
you to implement the following:
●
Back up the user program stored in RAM.
●
Retain bit memories, timers, counters, system data and data in variable data blocks.
●
Back up the internal clock.
You can achieve the same backup by connecting a DC voltage between 5 V DC and 15 V
DC to the "EXT. BATT." socket of the CPU.
Properties of the "EXT. BATT." input:
●
Reverse polarity protection
●
Short-circuit current limiting to 20 mA
For incoming supply at the "EXT. BATT" socket, you require a connecting cable with a 2.5
mm ∅ jack connector as shown in the figure below. Observe the polarity of the jack
connector.
3OXVSROH 0LQXVSROH
PPMDFNSOXJ
%ODFNRUEOXH!PLQXVSROH
5HG!SOXVSROH
Figure 5-2
Jack connector
Содержание SIMATIC S7-400H
Страница 24: ...Preface 1 1 Preface S7 400H 24 System Manual 03 2012 A5E00267695 11 ...
Страница 46: ...Getting Started 4 5 Special layout features of SIMATIC Manager S7 400H 46 System Manual 03 2012 A5E00267695 11 ...
Страница 120: ...Memory concept 10 1 Overview of the memory concept of S7 400H CPUs S7 400H 120 System Manual 03 2012 A5E00267695 11 ...
Страница 258: ...Communication 14 8 General issues regarding communication S7 400H 258 System Manual 03 2012 A5E00267695 11 ...
Страница 354: ...Synchronization modules 18 3 Selecting fiber optic cables S7 400H 354 System Manual 03 2012 A5E00267695 11 ...
Страница 434: ...Technical data 20 6 Runtimes of the FCs and FBs for redundant I Os S7 400H 434 System Manual 03 2012 A5E00267695 11 ...
Страница 460: ...Function modules and communication processors supported by the S7 400H S7 400H 460 System Manual 03 2012 A5E00267695 11 ...