Technical data
20.3 Technical specifications of the CPU 416–5H PN/DP; (6ES7 416-5HK06–0AB0)
S7-400H
408
System Manual, 03/2012, A5E00267695-11
Data areas and their retentivity
Total retentive data area (incl. bit memories,
timers, counters)
Total work and load memory (with backup
battery)
Bit memory
16 KB
Retentivity, configurable
From MB 0 to MB 16383
Preset retentivity
From MB 0 to MB 15
Clock memories
8 (1 bit memory byte)
Data blocks
Maximum 16000 (DB 0 reserved)
Number range 1 - 16000
Size
Maximum 64 KB
Local data (configurable)
Maximum 64 KB
Default
32 KB
Blocks
OBs
See instruction list
Size
Maximum 64 KB
Number of free-cycle OBs
OB 1
Number of time-of-day interrupt OBs
OB 10, 11, 12, 13, 14, 15, 16, 17
Number of time-delay interrupt OBs
OB 20, 21, 22, 23
Number of cyclic interrupts
OB 30, 31, 32, 33, 34, 35, 36, 37, 38
Number of process interrupt OBs
OB 40, 41, 42, 43, 44, 45, 46, 47
Number of DPV1 interrupt OBs
OB 55, 56, 57
Number of redundancy error OBs:
OB70, 72
Number of asynchronous error OBs
OB 80, 81, 82, 83, 84, 85, 86, 87, 88
Number of restart OBs
OB 100, 102
Number of synchronous error OBs
OB 121, 122
Nesting depth
Per priority class
24
Additional ones in an error OB
2
FBs
Maximum 8000
Number range 0 - 7999
Size
Maximum 64 KB
FCs
Maximum 8000
Number range 0 - 7999
Size
Maximum 64 KB
SDBs
Maximum 2048
Содержание SIMATIC S7-400H
Страница 24: ...Preface 1 1 Preface S7 400H 24 System Manual 03 2012 A5E00267695 11 ...
Страница 46: ...Getting Started 4 5 Special layout features of SIMATIC Manager S7 400H 46 System Manual 03 2012 A5E00267695 11 ...
Страница 120: ...Memory concept 10 1 Overview of the memory concept of S7 400H CPUs S7 400H 120 System Manual 03 2012 A5E00267695 11 ...
Страница 258: ...Communication 14 8 General issues regarding communication S7 400H 258 System Manual 03 2012 A5E00267695 11 ...
Страница 354: ...Synchronization modules 18 3 Selecting fiber optic cables S7 400H 354 System Manual 03 2012 A5E00267695 11 ...
Страница 434: ...Technical data 20 6 Runtimes of the FCs and FBs for redundant I Os S7 400H 434 System Manual 03 2012 A5E00267695 11 ...
Страница 460: ...Function modules and communication processors supported by the S7 400H S7 400H 460 System Manual 03 2012 A5E00267695 11 ...