Table of contents
S7-400H
6
System Manual, 03/2012, A5E00267695-11
5.5
Design and function of the memory cards .................................................................................. 65
5.6
Using memory cards ................................................................................................................... 67
5.7
Multi Point Interface MPI/DP (X1) ............................................................................................... 70
5.8
PROFIBUS DP interface (X2, X3)............................................................................................... 71
5.9
PROFINET interface (X5) ........................................................................................................... 71
5.10
Overview of the parameters for the S7-400H CPUs................................................................... 74
6
Special functions of a CPU 41x-H............................................................................................................ 77
6.1
Security levels ............................................................................................................................. 77
6.2
Encrypting blocks ........................................................................................................................ 79
6.3
Resetting the CPU to the factory state........................................................................................ 81
6.4
Updating the firmware without a memory card ........................................................................... 83
6.5
Firmware update in RUN mode .................................................................................................. 85
6.6
Reading service data .................................................................................................................. 86
7
PROFIBUS DP ........................................................................................................................................ 87
7.1
CPU 41x–H as PROFIBUS DP master ....................................................................................... 87
7.1.1
DP address ranges of CPUs 41x-H ............................................................................................ 88
7.1.2
CPU 41xH as PROFIBUS DP master......................................................................................... 88
7.1.3
Diagnostics of a CPU 41xH operating as PROFIBUS DP master.............................................. 91
8
PROFINET .............................................................................................................................................. 95
8.1
Introduction ................................................................................................................................. 95
8.2
PROFINET IO systems............................................................................................................... 97
8.3
Blocks in PROFINET IO.............................................................................................................. 99
8.4
System status lists for PROFINET IO ....................................................................................... 101
8.5
Device replacement without removable medium/programming device .................................... 103
8.6
Shared Device........................................................................................................................... 103
8.7
Media redundancy..................................................................................................................... 104
8.8
System redundancy .................................................................................................................. 106
9
Consistent data...................................................................................................................................... 111
9.1
Consistency of communication blocks and functions ............................................................... 112
9.2
Consistency rules for SFB 14 "GET" or read variable, and SFB 15 "PUT" or write variable.... 113
9.3
Consistent reading and writing of data from and to DP standard slaves/IO devices................ 113
10
Memory concept .................................................................................................................................... 117
10.1
Overview of the memory concept of S7-400H CPUs................................................................ 117
Содержание SIMATIC S7-400H
Страница 24: ...Preface 1 1 Preface S7 400H 24 System Manual 03 2012 A5E00267695 11 ...
Страница 46: ...Getting Started 4 5 Special layout features of SIMATIC Manager S7 400H 46 System Manual 03 2012 A5E00267695 11 ...
Страница 120: ...Memory concept 10 1 Overview of the memory concept of S7 400H CPUs S7 400H 120 System Manual 03 2012 A5E00267695 11 ...
Страница 258: ...Communication 14 8 General issues regarding communication S7 400H 258 System Manual 03 2012 A5E00267695 11 ...
Страница 354: ...Synchronization modules 18 3 Selecting fiber optic cables S7 400H 354 System Manual 03 2012 A5E00267695 11 ...
Страница 434: ...Technical data 20 6 Runtimes of the FCs and FBs for redundant I Os S7 400H 434 System Manual 03 2012 A5E00267695 11 ...
Страница 460: ...Function modules and communication processors supported by the S7 400H S7 400H 460 System Manual 03 2012 A5E00267695 11 ...