Technical data
20.2 Technical specifications of the CPU 414–5H PN/DP; (6ES7 414-5HM06–0AB0)
S7-400H
System Manual, 03/2012, A5E00267695-11
395
20.2
Technical specifications of the CPU 414–5H PN/DP;
(6ES7 414-5HM06–0AB0)
CPU and firmware version
Order number
6ES7 414–5HM06–0AB0
Firmware version
V 6.0
Corresponding programming package
as of STEP7 V 5.5 SP2 HF 1
see also Preface (Page 19)
Memory
Work memory
integrated
2 MB for code
2 MB for data
Load memory
integrated
512 KB RAM
Expandable FEPROM
With memory card (FLASH) 1 MB to 64 MB
Expandable RAM
With memory card (RAM) 256 KB to 64 MB
Battery backup
Yes, all data
Typical execution times
Execution times of
Bit instructions
18.75 ns
Word instructions
18.75 ns
Fixed-point arithmetic
18.75 ns
Floating-point arithmetic
37.5 ns
Timers/counters and their retentivity
S7 counters
2048
Retentivity, configurable
From C 0 to C 2047
Default
From C 0 to C 7
Counting range
0 to 999
IEC counters
Yes
Type
SFB
S7 timers
2048
Retentivity, configurable
From T 0 to T 2047
Default
No retentive timers
Time range
10 ms to 9990 s
IEC timers
Yes
Type
SFB
Содержание SIMATIC S7-400H
Страница 24: ...Preface 1 1 Preface S7 400H 24 System Manual 03 2012 A5E00267695 11 ...
Страница 46: ...Getting Started 4 5 Special layout features of SIMATIC Manager S7 400H 46 System Manual 03 2012 A5E00267695 11 ...
Страница 120: ...Memory concept 10 1 Overview of the memory concept of S7 400H CPUs S7 400H 120 System Manual 03 2012 A5E00267695 11 ...
Страница 258: ...Communication 14 8 General issues regarding communication S7 400H 258 System Manual 03 2012 A5E00267695 11 ...
Страница 354: ...Synchronization modules 18 3 Selecting fiber optic cables S7 400H 354 System Manual 03 2012 A5E00267695 11 ...
Страница 434: ...Technical data 20 6 Runtimes of the FCs and FBs for redundant I Os S7 400H 434 System Manual 03 2012 A5E00267695 11 ...
Страница 460: ...Function modules and communication processors supported by the S7 400H S7 400H 460 System Manual 03 2012 A5E00267695 11 ...