Communication
14.6 Communication via fault-tolerant S7 connections
S7-400H
System Manual, 03/2012, A5E00267695-11
245
Communication combinations
The following table shows the possible combinations of fault-tolerant connections via
Industrial Ethernet.
Local
connection
end point
Local network
connection
Used network
protocol
Remote
network connection
Remote
connection
end point
CPU 41xH V6 CPU-PN-SS
CP443-1 (EX11/20 )
CP443-1 ( X11/20)
TCP
TCP
TCP
CPU-PN-SS
CPU-PN-SS
CP443-1 ( EX11/20 )
TCP
TCP
TCP
CPU 41xH V6
CPU 41xH V6
CPU 41xH V6
S7 fault
tolerant
connection
via
ISOonTCP
CPU 41xH V6
CP443-1 (EX11/20) ISO
ISO
ISO
ISO
CP443-1 ( EX11/20 )
CP443-1 ( EX11/20 )
CP443-1 ( EX11 )
CP443-1 ( EX11 )
ISO
ISO
ISO
ISO
CPU 41xH V6
CPU 41xH V4.5
CPU 41xH V4.0
CPU 41xH V3.0
S7 fault
tolerant
connection
via ISO
PC station
with Simatic
Net CD
CP1623 as of V8.1.2 TCP
TCP
CPU-PN-SS
CP443-1 ( EX11/20 )
TCP
TCP
CPU 41xH V6
CPU 41xH V6
S7 fault
tolerant
connection
via
ISOonTCP
PC station
with Simatic
Net CD
CP1623 as of V8.1.2 ISO
ISO
ISO
ISO
CP443-1 ( EX11/20 )
CP443-1 ( EX11/20 )
CP443-1 ( EX11 )
CP443-1 ( EX11 )
ISO
ISO
ISO
ISO
CPU 41xH V6
CPU 41xH V4.5
CPU 41xH V4.0
CPU 41xH V3.0
S7 fault
tolerant
connection
via ISO
PC station
with Simatic
Net CD
CP1623 up to V7.x
ISO
ISO
ISO
ISO
CP443-1 ( EX11/20 )
CP443-1 ( EX11/20 )
CP443-1 ( EX11 )
CP443-1 ( EX11 )
ISO
ISO
ISO
ISO
CPU 41xH V6
CPU 41xH V4.5
CPU 41xH V4.0
CPU 41xH V3.0
S7 fault
tolerant
connection
via ISO
Configuration
The availability of the system, including the communication, is set during configuration. Refer
to the STEP 7 documentation to find out how to configure connections.
Only S7 communication is used for fault-tolerant S7 connections. To set this up, open the
"New Connection" dialog box, then select "S7 Connection Fault-Tolerant" as the type.
The number of required redundant subconnections is determined by STEP 7 as a function of
the redundancy nodes. Up to four redundant connections can be generated, if supported by
the network. Higher redundancy cannot be achieved even by using more CPs.
In the "Properties - Connection" dialog box you can also modify specific properties of a fault-
tolerant connection if necessary. When using more than one CP, you can also route the
connections in this dialog box. This may be practical, because by default all connections are
routed initially through the first CP. If all the connections are busy there, any further
connections are routed via the second CP, etc.
Содержание SIMATIC S7-400H
Страница 24: ...Preface 1 1 Preface S7 400H 24 System Manual 03 2012 A5E00267695 11 ...
Страница 46: ...Getting Started 4 5 Special layout features of SIMATIC Manager S7 400H 46 System Manual 03 2012 A5E00267695 11 ...
Страница 120: ...Memory concept 10 1 Overview of the memory concept of S7 400H CPUs S7 400H 120 System Manual 03 2012 A5E00267695 11 ...
Страница 258: ...Communication 14 8 General issues regarding communication S7 400H 258 System Manual 03 2012 A5E00267695 11 ...
Страница 354: ...Synchronization modules 18 3 Selecting fiber optic cables S7 400H 354 System Manual 03 2012 A5E00267695 11 ...
Страница 434: ...Technical data 20 6 Runtimes of the FCs and FBs for redundant I Os S7 400H 434 System Manual 03 2012 A5E00267695 11 ...
Страница 460: ...Function modules and communication processors supported by the S7 400H S7 400H 460 System Manual 03 2012 A5E00267695 11 ...