MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.3 Real Time Clock (RTC)
10.3.5.1.10
RTCTMR_TRIM_CTRL
RTCTMR_TRIM_CTRL.trim_enable_r
Field
Bits
Default
Access
Description
trim_enable_r
0
0 (RTC POR only)
R/W
Enable RTL Trim of RTC Timer
• 0: Trim disabled
• 1: Trim enabled
Any changes must occur with RTC timer disabled.
RTCTMR_TRIM_CTRL.trim_faster_ovr_r
Field
Bits
Default
Access
Description
trim_faster_ovr_r
1
0 (RTC POR only)
R/W
Force RTC Trim to Faster
• 0: Disabled; trim direction controlled by high bit of trim value.
• 1: Force trim to always occur in faster direction.
Any changes must occur with RTC timer disabled.
RTCTMR_TRIM_CTRL.trim_slower_r
Field
Bits
Default
Access
Description
trim_slower_r
2
0 (RTC POR only)
R/O
RTC Trim Direction Status
• 0: Trim adjustments will cause RTC to count faster.
• 1: Trim adjustments will cause RTC to count slower.
Rev.1.3 April 2015
Maxim Integrated
Page 581
Содержание MAX32600