MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.1 System Clock
Dynamic clock gating control.
• 00b: Clock Off
• 01b: Dynamic Clock Gating Enabled
• 1xb: Clock On
10.1.5.1.30
CLKMAN_CLK_GATE_CTRL2
CLKMAN_CLK_GATE_CTRL2.crc_clk_gater
Field
Bits
Default
Access
Description
crc_clk_gater
1:0
01b
R/W
Clock Gating Control for CRC16/32 Engine
Dynamic clock gating control.
• 00b: Clock Off
• 01b: Dynamic Clock Gating Enabled
• 1xb: Clock On
CLKMAN_CLK_GATE_CTRL2.tpu_clk_gater
Field
Bits
Default
Access
Description
tpu_clk_gater
3:2
01b
R/W
Clock Gating Control for TPU
Dynamic clock gating control.
• 00b: Clock Off
• 01b: Dynamic Clock Gating Enabled
Rev.1.3 April 2015