MAX32600 User’s Guide
Analog Front End
8.3 ADC
Field
Bits
Default
Access
Description
Used to control the total number of samples collected when adc_mode is x000b or x001b. If the decimation filter is enabled, this field still controls the total number of
samples (data points) collected, but the sample data output to the ADC FIFO will be a smaller number of samples, depending on the current decimation filter setting.
Minimum valid setting for this field is 0001h. 0000h is not a valid setting for this field.
8.3.5.1.4
ADC_TG_CTRL1
ADC_TG_CTRL1.pga_acq_cnt
Field
Bits
Default
Access
Description
pga_acq_cnt
3:0
0001b
R/W
PGA Acquisition Window Count
This field sets the number of ADC clocks between the PGA entering its gain phase and the PGA entering its acquisition phase.
ADC_TG_CTRL1.fifo_af_cnt
Field
Bits
Default
Access
Description
fifo_af_cnt
7:4
0111b
R/W
ADC FIFO Almost Full Threshold Control
Sets the threshold value used to trigger the FIFO Almost Full condition. The actual threshold value used is fifo16.
ADC_TG_CTRL1.adc_brst_cnt
Field
Bits
Default
Access
Description
adc_brst_cnt
10:8
000b
R/W
ADC Burst Count Setting
• 000b: 1 sample
• 001b: 2 samples
Rev.1.3 April 2015