MAX32600 User’s Guide
Trust Protection Unit (TPU)
11.2 Modular Arithmetic Accelerator (MAA)
Field
Bits
Default
Access
Description
seg_res
27:24
0000b
R/W
Result Memory Segment Select
These bits select the memory segment for the results output. (Same as select settings for Operand A)
MAA_CTRL.seg_tmp
Field
Bits
Default
Access
Description
seg_tmp
31:28
0000b
R/W
Temporary Memory Segment Select
These bits select the memory segment which is used as scratch / temporary space by the micro MAA. (Same as select settings for Operand A)
11.2.1.1.2
MAA_MAWS
MAA_MAWS.modlen
Field
Bits
Default
Access
Description
modlen
9:0
0
R/W
MAA Word Size
Selects bit size for modular operation; valid settings are 1 to 512.
MAA_MAWS.byteswap
Field
Bits
Default
Access
Description
byteswap
15
0
R/W
Big Endian Byte Mode
• 0: Do not swap byte order when transferring to/ from MAA memory space.
• 1: Swap byte order for MAA memory transfers.