![Maxim Integrated MAX32600 Скачать руководство пользователя страница 674](http://html1.mh-extra.com/html/maxim-integrated/max32600/max32600_user-manual_1744482674.webp)
MAX32600 User’s Guide
Flash Controller and Instruction Cache
14.1 Registers (FLC)
Field
Bits
Default
Access
Description
started_ie
8
0
R/W
Flash Operation Started Interrupt Enable
• 0: Interrupt disabled.
• 1: Setting the Flash Operation Started bit to 1 will cause the FLC to generate an interrupt.
FLC_INTR.failed_ie
Field
Bits
Default
Access
Description
failed_ie
9
0
R/W
Flash Operation Failed Interrupt Enable
• 0: Interrupt disabled.
• 1: Setting the Flash Operation Failed bit to 1 will cause the FLC to generate an interrupt.
14.1.1.5
FLC_FDATA
Default
Access
Description
00000000h
R/W
Flash Operation Data Register
This register is used as an input parameter for various flash controller operations.
14.1.1.6
FLC_PERFORM
FLC_PERFORM.fast_read_mode_en
Field
Bits
Default
Access
Description
fast_read_mode_en
8
0
R/W
Fast Read Mode Enable
Rev.1.3 April 2015
Maxim Integrated
Page 656
Содержание MAX32600