MAX32600 User’s Guide
Analog Front End
8.3 ADC
Field
Bits
Default
Access
Description
adc_tst_en
4
0
R/W
Reserved Field (Do Not Modify)
This field should not be modified by the user. For proper operation, this field must be left at its default value.
ADC_CTRL0.adc_strt_mode
Field
Bits
Default
Access
Description
adc_strt_mode
5
0
R/W
ADC Start Mode Control
ADC mode control for start of data collection.
• 0: Start when cpu_adc_start is set
• 1: Start controlled by PulseTrain[15] output
ADC_CTRL0.range
Field
Bits
Default
Access
Description
range
6
0
R/W
ADC Range Control (Bipolar Mode Only)
• 0: Bipolar operation from -Vref/2 to +Vref/2
• 1: Bipolar operation from -Vref to +Vref
ADC_CTRL0.bi_pol
Field
Bits
Default
Access
Description
bi_pol
7
0
R/W
ADC Unipolar/Bipolar Mode Select
Rev.1.3 April 2015
Maxim Integrated
Page 424
Содержание MAX32600