![Maxim Integrated MAX32600 Скачать руководство пользователя страница 311](http://html1.mh-extra.com/html/maxim-integrated/max32600/max32600_user-manual_1744482311.webp)
MAX32600 User’s Guide
Communication Peripherals
7.3 UART
• 1:Baud clock generation enabled.
7.3.9.1.2
UARTn_STATUS
UARTn_STATUS.tx_busy
Field
Bits
Default
Access
Description
tx_busy
0
0
R/O
TX Busy
1: The UART is transmitting data.
UARTn_STATUS.rx_busy
Field
Bits
Default
Access
Description
rx_busy
1
0
R/O
RX Busy
1: The UART is receiving data.
UARTn_STATUS.rx_fifo_empty
Field
Bits
Default
Access
Description
rx_fifo_empty
4
1
R/O
RX FIFO Empty
1: The Receive FIFO is empty.
UARTn_STATUS.rx_fifo_full
Field
Bits
Default
Access
Description
rx_fifo_full
5
0
R/O
RX FIFO Full
Rev.1.3 April 2015
Maxim Integrated
Page 293
Содержание MAX32600
Страница 1: ...MAX32600 User s Guide April 2015...