MAX32600 User’s Guide
Communication Peripherals
7.4 USB Device Interface
USB_SETUP1.byte6
Field
Bits
Default
Access
Description
byte6
23:16
00h
R/O
SETUP Packet Byte 6
Byte 6 of the last SETUP packet received by the USB controller.
USB_SETUP1.byte7
Field
Bits
Default
Access
Description
byte7
31:24
00h
R/O
SETUP Packet Byte 7
Byte 7 of the last SETUP packet received by the USB controller.
7.4.4.1.17
USB_EP
USB_EP.ep_dir
Field
Bits
Default
Access
Description
ep_dir
1:0
11b
R/W
Endpoint Direction
For Endpoint 0 - Read-only; always set to 11b (CONTROL pipe accepting IN, OUT, and STATUS packets) for Endpoint 0.
For other endpoints (1 through 7) -
• 00b: Endpoint is disabled.
• 01b: Endpoint is configured for OUT transfers.
• 10b: Endpoint is configured for IN transfers.
• 11b: Reserved (only EP0 can be set to CONTROL mode).
Rev.1.3 April 2015