MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.1 System Clock
• 1001b: CLK = (System Clock Source / 256)
• other: CLK = (System Clock Source / 1)
This clock is disabled by default following reset.
10.1.5.1.15
CLKMAN_CLK_CTRL_8_LCD_CHPUMP
CLKMAN_CLK_CTRL_8_LCD_CHPUMP.lcd_clk_scale
Field
Bits
Default
Access
Description
lcd_clk_scale
3:0
0000b
R/W
Control Settings for CLK8 - LCD Charge Pump
Clock
• 0000b: CLK is Disabled
• 0001b: CLK = (System Clock Source / 1)
• 0010b: CLK = (System Clock Source / 2)
• 0011b: CLK = (System Clock Source / 4)
• 0100b: CLK = (System Clock Source / 8)
• 0101b: CLK = (System Clock Source / 16)
• 0110b: CLK = (System Clock Source / 32)
• 0111b: CLK = (System Clock Source / 64)
• 1000b: CLK = (System Clock Source / 128)
• 1001b: CLK = (System Clock Source / 256)
• other: CLK = (System Clock Source / 1)
This clock is disabled by default following reset.
10.1.5.1.16
CLKMAN_CLK_CTRL_9_PUF
CLKMAN_CLK_CTRL_9_PUF.puf_clk_scale
Rev.1.3 April 2015