8.3 ADC
Some of the parameters that can be set for ADC conversion operations in PMU or CPU control modes include:
• Sample rate control
• Oversampling and decimation filter operations
–
The burst sample rate is always the maximum sample rate
–
Programmable burst length for averaging operations
• Channel scan capability, allowing the ADC to switch between multiple channel sources in a conversion sequence
–
Up to eight scan descriptors can be used, allowing eight different channel configurations in a sequence
–
Separate channel select, single-ended or differential mode select, and PGA gain settings for each scan descriptor
• Continuous or Pulsed scanning modes (Pulsed includes a sleep period between conversion bursts)
8.3.4
ADC Configuration
Using the ADC requires setting up the ADC for the specific mode required for the measurement. The following are the steps required to configure and use the ADC.
Each of these are described below with details on configuration options.
1.
Set up the ADC Peripheral Clock
2.
3.
Set up input mode (i.e., single-ended or differential mode)
4.
Configure the Input Mux for the channels that will be measured
5.
Set up the ADC scan mode (single, continuous, burst, etc.)
6.
7.
Configure the PGA (bypass, gain, etc.)
8.
9.